icelab_PRO Series
The purely electric professional multi-room system with real -110 °C!

Built for the highest demands and greatest possible success. Whether as a 2-room or 3-room system, if performance and quality count, then the models of the icelab_PRO series are just right.

კატეგორია:

აღწერა

Professional multi-room systems with plenty of space
The icelab multi-room systems of the PRO series always consist of the actual treatment room with -110 ° C and one or two anterooms. The anteroom of the 2-room model has a temperature of -60 ° C, and the 3-room solution has one anteroom with -10 and one with -60 ° C for the least possible loss of cold when the doors are opened. The antechambers allow less humid outside air to enter the system, which reduces fogging and has a positive effect on the system’s efficiency.
Thanks to their highly efficient 3-stage refrigeration cascade, the icelab PRO models reach up to -110 ° C in the main room: there is enough space for up to four people at the same time. A touch control panel gives the operator an overview of the most important functions and values of the system at all times. This makes the icelab_PRO models particularly suitable for operators from the health industry, for professional sports facilities, hotels, spas with medium to high capacity utilisation.
  • Space for up to four people per application.
  • Exclusive design – exterior colour in silver-grey (RAL 9006).
  • Automatic ventilation / drying – Simple and convenient after use. No manual opening/closing of the door necessary.
  • Easy operation – Control of the system via touch panel on the cabin.
  • Extensive optional equipment – e.g. wooden interior panelling for a high-quality look, heat recovery.
  • Individual system planning – Adapted technology and dimensions according to individual local conditions.
icelab_PRO2

The 2-room system with up to -110 °C for optimal effects

icelab_PRO3

Maximum performance with the 3-room system for up to 4 people at the same time.

icelab_PRO²

Occupancy
1 – 4 persons

Air temperature in the cabin up to
-60 °C / -110 °C

Precooling1 time approx.
150 min

Duration of use per day up to2
15h

Dimensions (W x D x H)3
4200 x 2400 x 2550 mm

Weight
1450 kg

Supply voltage4
380-400 V / 3 / 50 Hz – 460 V / 3 / 60 Hz

Power connection
63 A

Standard cooling
Water

icelab_PRO³

Occupancy
1 – 4 persons

Air temperature in the cabin up to
– 10 °C / -60 °C / -110 °C

Precooling1 time approx.
180 min

Duration of use per day up to2
15h

Dimensions (W x D x H)3
6000 x 2400 x 2550 mm

Weight
2400 kg

Supply voltage4
380-400 V / 3 / 50 Hz – 460 V / 3 / 60 Hz

Power connection
63 A

Standard cooling
Water

1 Pre-cooling time depends on piping lengths, climatic conditions, and optional equipment.
2 Treatment time depends on the number of applications carried out and can be restarted after drying.
3 Adaptation to customer-specific premises possible.
4 Voltage is adaptable to almost any existing voltage with transformers. Please enquire about your possibilities.